Industrial Complex Post-Fire Structural Evaluation

Lackawanna, NY

Project Objective

Following a large-scale fire at an industrial complex, the client required evaluation of the facility in order to determine the extent of damage to structural steel members.

Unique Project Features

The complex consists of a number of separate structures, formerly part of the Bethlehem Steel facilities.

Encorus Group Solution

Encorus performed a structural engineering evaluation of the facility over multiple days in order to determine the limits of the fire damage, focusing on structural steel members. Recommendations were made as to which areas should be subject to further, more intensive investigation.

Specific Project Tasks

  • On-site investigations
  • Recommendations for further investigation
  • Preparation of a report detailing the findingd